GNH USA

Europe — EMA

Mibg (123i) Curium Netherlands

GNH USA supplies Mibg (123i) Curium Netherlands (Iobenguane I-123), a radiopharmaceutical for cardiac sympathetic innervation and neuroblastoma imaging.

Iodine (123i) Iobenguane

Request sourcing

1
Pack/s

What is Iodine (123i) Iobenguane?

Iobenguane I-123, the active ingredient in Mibg (123i) Curium Netherlands, is a radiopharmaceutical presented as an injectable solution for intravenous use. It enables visualization of sympathetic nerve activity for cardiac and neuroblastoma imaging in patients undergoing nuclear medicine studies.

GNH USA supplies Mibg (123i) Curium Netherlands as a licensed, GDP-compliant international pharmaceutical supplier serving hospitals, oncology centres and nuclear medicine clinics worldwide.

What is Iodine (123i) Iobenguane used for?

Mibg (123i) Curium is used in nuclear medicine to assess sympathetic nerve function in specific disease contexts. - Cardiac sympathetic innervation imaging: visualizes myocardial sympathetic nerve distribution to aid diagnosis and risk assessment. - Heart failure risk stratification: provides functional data on cardiac sympathetic activity to help guide therapeutic decisions. - Neuroblastoma imaging: detects neuroblastoma lesions by targeting the norepinephrine transporter in tumor cells.

What are the side effects of Iodine (123i) Iobenguane?

Adverse reactions may occur following intravenous administration of Iobenguane I-123.

Common Side Effects: - Nausea: mild and transient. - Headache: occasional during or after injection. - Flushing: brief skin reddening. - Injection site pain: mild discomfort at the venipuncture site. - Transient hypertension: short‑lived rise in blood pressure. - Dizziness: mild light‑headedness.

Serious or Rare Side Effects: - Anaphylaxis: severe allergic reaction requiring immediate medical attention. - Severe hypotension: marked drop in blood pressure. - Radiation‑induced tissue injury: localized damage at high exposure sites. - Arrhythmia: abnormal heart rhythm. - Severe skin reaction: extensive rash or urticaria. - Thyroid dysfunction: abnormal thyroid hormone levels due to iodine exposure.

What precautions apply to Iodine (123i) Iobenguane?

Prior to use, clinicians should evaluate patient‑specific factors and follow safety guidelines. - Pregnancy: avoid unless clearly needed, as fetal radiation exposure is possible. - Breastfeeding: discontinue nursing for an appropriate interval after administration. - Radiation safety: limit staff exposure and follow local radiation protection protocols. - Renal function: assess because the tracer is cleared renally. - Thyroid blocking: consider iodine blockade in patients at risk for thyroid uptake. - Store at 2-8°C: keep refrigerated, protect from light, do not freeze or shake.

What does Iodine (123i) Iobenguane interact with?

Iobenguane I-123 may interact with other agents that affect norepinephrine pathways or iodine handling.

Major Interactions (Avoid): - Sympathomimetic drugs (e.g., epinephrine): compete for NET uptake and may reduce image quality. - Iodine‑containing contrast agents: can interfere with tracer distribution and imaging interpretation. - Thyroid hormone therapy: may alter iodine metabolism and affect tracer uptake.

Moderate Interactions (Monitor Closely): - Beta‑blockers: may modify sympathetic activity and influence tracer accumulation. - Calcium channel blockers: could affect cardiac perfusion and imaging results. - Diuretics: may change renal clearance of the radiotracer.

Frequently asked questions

What is Mibg (123i) Curium used for?+
Mibg (123i) Curium is a radiopharmaceutical used in nuclear medicine to image sympathetic nerve activity. It is primarily employed for cardiac sympathetic innervation imaging to assess heart disease and for detecting neuroblastoma tumors by visualizing norepinephrine transporter expression.
How does Iobenguane I-123 work?+
Iobenguane I-123 mimics norepinephrine and is taken up by adrenergic nerve terminals via the norepinephrine transporter. The iodine‑123 label emits gamma radiation, which is captured by SPECT cameras, producing detailed images of sympathetic innervation in the heart or neuroblastoma tissue.
What is the usual dose of Mibg (123i) Curium?+
The administered activity of Iobenguane I-123 is determined by the prescribing physician or nuclear medicine specialist based on the patient's weight, the imaging protocol, and regulatory guidelines. Exact dosing is individualized and not standardized in public documentation.
Is Mibg (123i) Curium safe during pregnancy or breastfeeding?+
Because Iobenguane I-123 involves ionizing radiation, it is generally avoided in pregnancy unless the diagnostic benefit outweighs the risk. Breastfeeding mothers should discontinue nursing for a period recommended by the treating physician to prevent infant radiation exposure.
How do I order Mibg (123i) Curium from GNH USA?+
To place an order, submit an enquiry on the product page at gnh-usa.com with the required quantity. GNH USA works with hospitals, pharmacies and procurement teams worldwide, verifies trade or institutional credentials, and then provides pricing, availability, shipping details (including cold‑chain if needed) and import documentation.
How does Mibg (123i) Curium compare with other cardiac imaging agents?+
Compared with agents such as 123I‑MIBG, Iobenguane I-123 offers similar NET targeting but may differ in specific activity, imaging protocols, and regulatory status. Choice of agent depends on local availability, imaging equipment, and the clinical question; both provide valuable information on sympathetic innervation.
What are the storage and handling requirements for Mibg (123i) Curium?+
The product must be stored refrigerated at 2‑8 °C, protected from light, and never frozen or shaken. It should be kept in its original container until use and handled by trained personnel in a radiation‑controlled environment.
How is Mibg (123i) Curium administered?+
Mibg (123i) Curium is administered as a single intravenous injection under sterile conditions. The dose is prepared by a qualified radiopharmacy, and imaging is performed shortly after injection according to the specific nuclear medicine protocol.
What are the most serious risks associated with Mibg (123i) Curium?+
Serious risks include severe allergic reactions (anaphylaxis), significant hypotension or hypertension, radiation‑induced tissue injury, arrhythmias, and rare thyroid dysfunction due to iodine exposure. Patients should be monitored closely during and after administration.
Who should not receive Mibg (123i) Curium?+
Patients with known hypersensitivity to iodine or Iobenguane, those who are pregnant unless absolutely necessary, and individuals with uncontrolled thyroid disorders should avoid the product. Contra‑indications are determined by the prescribing clinician based on medical history.
Information provided on this page is for educational use by procurement and clinical professionals. Always consult a licensed healthcare provider for medical advice and prescribing decisions. GNH USA supplies this product subject to applicable regulatory and licensing requirements.

Product details

Drug
Iodine (123i) Iobenguane
Route
Intravenous Use
Manufacturer
Curium Netherlands B.V.
Origin
EU

Related products