GNH USA

Europe — EMA

Iomeron

GNH USA supplies Iomeron (Iomeprol), an iodinated contrast media for angiography, arthrography and CT imaging, enhancing radiographic detail.

Iomeprol

Request sourcing

1
Pack/s

What is Iomeprol?

Iomeprol, the active ingredient in Iomeron, is an iodinated contrast media presented as an injectable solution for intraarterial, intraarticular, and intravenous use. It enhances radiographic imaging contrast in patients undergoing angiography, arthrography, or CT scans.

GNH USA supplies Iomeron as a licensed, GDP‑compliant international pharmaceutical supplier serving hospitals, pharmacies and clinics worldwide.

What is Iomeprol used for?

Iomeron is used as a radiographic contrast agent to improve visualization in several imaging pathways.

- Angiography: provides clear vessel delineation for diagnostic and interventional procedures. - Arthrography: enhances joint space imaging to assess cartilage, ligaments, and intra‑articular structures. - CT imaging: increases tissue radiodensity, allowing better differentiation of organs and lesions during computed tomography scans.

What are the side effects of Iomeprol?

Iomeron may cause a range of reactions, from mild to severe, following intravascular administration.

Common Side Effects: - Warm sensation or flushing at the injection site. - Nausea or mild vomiting. - Transient headache. - Mild itching or skin rash. - Temporary elevation of serum creatinine. - Mild hypotension.

Serious or Rare Side Effects: - Severe allergic reaction (anaphylaxis) with respiratory distress. - Acute kidney injury, especially in patients with pre‑existing renal impairment. - Cardiac arrhythmias or myocardial ischemia. - Pulmonary edema. - Severe hypotension or shock. - Neurological disturbances such as seizures.

What precautions apply to Iomeprol?

Prior to using Iomeron, clinicians should assess patient risk factors and follow recommended handling practices.

- Renal function assessment: evaluate serum creatinine and eGFR before administration. - Allergy history: screen for prior reactions to iodinated contrast agents. - Hydration status: ensure adequate patient hydration to reduce nephrotoxicity risk. - Concomitant nephrotoxic drugs: consider dose adjustment or alternative imaging. - Pregnancy and lactation: use only if clearly needed, after risk‑benefit evaluation. - Store at 2‑8°C: keep refrigerated, protect from light, do not freeze or shake.

What does Iomeprol interact with?

Iomeron can interact with other agents that affect renal function or hypersensitivity risk.

Major Interactions (Avoid): - Loop diuretics combined with Iomeron may exacerbate renal impairment. - High‑dose NSAIDs: increase risk of contrast‑induced nephropathy. - Metformin: may precipitate lactic acidosis in patients with reduced renal clearance.

Moderate Interactions (Monitor Closely): - ACE inhibitors or ARBs: monitor renal function and electrolytes. - Beta‑blockers: may mask early signs of anaphylaxis. - Thyroid hormones: iodine load can affect thyroid function tests.

Frequently asked questions

What is Iomeron used for?+
Iomeron is an iodinated contrast agent used to improve image quality during diagnostic procedures such as angiography, arthrography, and computed tomography (CT) scans. By increasing the radiodensity of blood vessels, joints, and organs, it helps radiologists distinguish anatomical structures and detect pathology more accurately.
How does Iomeprol work in Iomeron?+
Iomeprol contains iodine atoms that absorb X‑ray photons. When injected, the iodine‑rich solution distributes in the vascular and extracellular compartments, raising the attenuation of targeted tissues. This creates a contrast difference on X‑ray‑based images, allowing clearer visualization of vessels, joints, and organ details.
What is the usual dose of Iomeron?+
The dose of Iomeron is determined by the prescribing physician based on the specific imaging study, patient weight, renal function, and the required level of contrast. Healthcare professionals calculate the appropriate volume and concentration to achieve optimal image quality while minimizing risk.
Is Iomeron safe during pregnancy or breastfeeding?+
The safety of Iomeron in pregnancy and lactation has not been definitively established. It should be used only when clearly necessary, after a careful risk‑benefit assessment by the treating physician. If administered to a nursing mother, the infant may be exposed through breast milk, and clinical judgment is required.
How do I order Iomeron from GNH USA?+
To order Iomeron, submit an enquiry on the product page at gnh-usa.com, specifying the required quantity. GNH USA works with hospitals, pharmacies, and procurement teams worldwide, verifies trade or institutional credentials, and then provides pricing, availability, shipping details (including cold‑chain if needed), and import documentation.
How does Iomeron compare with other iodinated contrast agents?+
Iomeron (Iomeprol) is a low‑osmolality, non‑ionic iodinated contrast medium, offering a favorable safety profile compared with older high‑osmolality agents. It provides comparable image enhancement while reducing the incidence of discomfort, warmth sensations, and renal toxicity, making it a preferred choice for many diagnostic imaging procedures.
What are the storage and handling requirements for Iomeron?+
Iomeron should be stored at 2‑8 °C in a refrigerator, protected from light. Do not freeze or shake the vial. Keep the product in its original packaging until use, and discard any solution that appears discolored or contains particles.
How is Iomeron administered to patients?+
Iomeron is administered by a qualified healthcare professional via intra‑arterial, intra‑articular, or intravenous injection, depending on the imaging study. The injection is typically performed using a power injector or manual bolus, following aseptic technique and the dosage prescribed by the radiologist or physician.
What are the most serious risks associated with Iomeron?+
The most serious risks include severe allergic reactions (anaphylaxis), contrast‑induced nephropathy leading to acute kidney injury, and cardiovascular events such as arrhythmias or hypotension. Patients with known iodine allergy, impaired renal function, or uncontrolled cardiac disease require careful assessment before use.
Who should not receive Iomeron?+
Iomeron is contraindicated in patients with a documented hypersensitivity to iodinated contrast media, those with uncontrolled severe renal impairment, and individuals who have experienced prior severe anaphylactic reactions to similar agents. Clinicians should also avoid use in patients where the diagnostic benefit does not outweigh the potential risks.
Information provided on this page is for educational use by procurement and clinical professionals. Always consult a licensed healthcare provider for medical advice and prescribing decisions. GNH USA supplies this product subject to applicable regulatory and licensing requirements.

Product details

Drug
Iomeprol
Route
Intraarterial Use , Intraarticular Use , Intraveno
Manufacturer
Bracco Imaging S.P.A.
Origin
EU

Related products