GNH USA

Europe — EMA

Glukóza B. Braun

Glukóza B. Braun is an IV glucose monohydrate solution used for hypoglycemia, parenteral nutrition, and fluid replacement. Learn indications, safety, and dosing considerations.

Glucose Monohydrate

Request sourcing

1
Pack/s

What is Glucose Monohydrate?

Glukóza B. Braun is a sterile solution for injection containing glucose monohydrate as the active ingredient. It is supplied as a parenteral carbohydrate solution in a ready‑to‑use intravenous formulation, marketed in the European Union. The product is prescribed by healthcare professionals for rapid glucose supplementation and fluid replacement in clinical settings. It is available in concentrations for intravenous administration and is classified as an Rx excipient used in nutrition regimens.

What is Glucose Monohydrate used for?

Glukóza B. Braun is indicated for clinical situations that require rapid elevation of blood glucose or provision of carbohydrate calories intravenously.

- Treatment of acute hypoglycemia when oral glucose is not feasible. - Component of parenteral nutrition formulas to supply energy. - Fluid and electrolyte replacement in patients unable to tolerate oral intake. - Support during surgical procedures or critical care when glucose infusion is required. - Adjunctive therapy for certain metabolic disorders under specialist supervision. - Dilution and administration as part of intravenous fluid therapy to maintain caloric balance in long‑term hospitalized patients.

What are the side effects of Glucose Monohydrate?

The safety profile of Glukóza B. Braun reflects the expected pharmacologic response to intravenous glucose and includes both frequent mild reactions and rare serious events.

Common: - Transient increase in blood glucose concentration. - Mild infusion site discomfort or erythema. - Electrolyte shifts such as low potassium (hypokalemia) secondary to insulin release. - Nausea or abdominal discomfort in susceptible individuals. - Headache or dizziness. - Transient feeling of warmth or flushing during infusion.

Serious: - Severe hyperglycemia leading to osmotic diuresis or ketoacidosis. - Anaphylactic or severe hypersensitivity reaction (rash, bronchospasm, hypotension). - Fluid overload causing pulmonary edema, especially in patients with cardiac or renal impairment. - Severe electrolyte disturbances such as profound hypokalemia or hypernatremia.

What precautions apply to Glucose Monohydrate?

When administering Glukóza B. Braun, clinicians should observe specific precautions to minimize risks related to glucose overload, fluid balance, and patient-specific conditions.

- Assess baseline blood glucose and adjust infusion rate to avoid hyperglycemia. - Evaluate renal and cardiac function before large‑volume administration to prevent fluid overload. - Monitor serum electrolytes, especially potassium and sodium, during and after infusion. - Use aseptic technique; discard any solution that appears discolored or contains particles. - Consider contraindications such as known hypersensitivity to glucose solutions. - Adjust dose in patients receiving insulin or other glucose‑lowering agents. - Avoid rapid infusion in neonates and infants unless specifically indicated.

What does Glucose Monohydrate interact with?

Glukóza B. Braun may interact with other medications that affect glucose metabolism, fluid status, or electrolyte balance, requiring careful management.

Avoid: - Co‑administration with high‑dose insulin boluses without monitoring can cause severe hypoglycemia. - Simultaneous infusion of hypertonic saline solutions may exacerbate hypernatremia.

Use with caution: - Concurrent use of diuretics may increase the risk of electrolyte disturbances. - Patients receiving catecholamines or glucocorticoids may experience altered glucose requirements. - Fluid replacement therapy in heart failure patients should be titrated to avoid volume overload. - Parenteral nutrition regimens containing other carbohydrate sources should be balanced to prevent excess caloric intake.

Frequently asked questions

What concentration is Glukóza B. Braun supplied in for intravenous use?+
Glukóza B. Braun is typically provided as a sterile solution containing a standard concentration of glucose monohydrate, such as 5% or 10% w/v, depending on the specific product packaging approved in the European Union.
How is Glukóza B. Braun used to treat acute hypoglycemia in a hospital setting?+
In acute hypoglycemia, the solution is administered intravenously at a rate that quickly raises blood glucose to a safe level, often as a bolus followed by a controlled infusion, while the patient’s glucose is monitored.
Can Glukóza B. Braun be given to pediatric patients?+
Glukóza B. Braun may be used in pediatric patients under the supervision of a pediatric specialist, with dosing and infusion rates adjusted for age, weight, and clinical condition.
What laboratory parameters should be monitored during a Glukóza B. Braun infusion?+
Blood glucose, serum electrolytes (especially potassium and sodium), and renal function should be checked regularly to detect hyperglycemia, electrolyte shifts, or fluid overload.
How does intravenous Glukóza B. Braun differ from oral glucose tablets?+
Intravenous Glukóza B. Braun delivers glucose directly into the bloodstream, providing a rapid rise in blood sugar, whereas oral tablets must be absorbed through the gastrointestinal tract, resulting in a slower effect.
What are the most common side effects observed with Glukóza B. Braun infusion?+
Common side effects include transient hyperglycemia, mild infusion site irritation, electrolyte changes such as hypokalemia, and occasional nausea or dizziness.
When should Glukóza B. Braun be avoided in patients with heart failure?+
In patients with severe heart failure, the solution should be avoided or used with extreme caution because the added fluid volume can exacerbate pulmonary edema and worsen cardiac function.
How does Glukóza B. Braun interact with insulin therapy?+
Because the solution raises blood glucose, concurrent insulin therapy may require dose adjustments and close glucose monitoring to prevent hypoglycemia.
What storage conditions are recommended for Glukóza B. Braun?+
The product should be stored at controlled room temperature, protected from light, and used before the expiration date printed on the label. Once opened, it must be used within the time frame specified by the manufacturer.
Is Glukóza B. Braun compatible with other intravenous fluids such as saline or electrolyte solutions?+
Glukóza B. Braun can be mixed with compatible IV fluids, but compatibility should be verified for each combination, especially when mixing with hypertonic solutions, to avoid precipitation or osmolarity issues.
Information provided on this page is for educational use by procurement and clinical professionals. Always consult a licensed healthcare provider for medical advice and prescribing decisions. GNH USA supplies this product subject to applicable regulatory and licensing requirements.

Product details

Drug
Glucose Monohydrate
Route
Intravenous Use
Manufacturer
B.Braun Melsungen Ag
Origin
EU

Related products